NXR-S Simple Logic Safety I/O Blocks - Omron Industrial Automation
Modules

NXR-S Simple Logic Safety I/O Blocks

Omron Industrial AutomationTCC-2026-09-28-nxr-s-simple-logic-safety-i-o-blocks

NXR-S is a family of IP67 safety remote I/O blocks with built-in logic for distributed control and centralized management.

EHBSA Series Capacitors

Introduction

Omron Industrial Automation’s NXR-S Simple Logic Safety I/O Blocks are IP67-rated safety remote I/O modules for distributed industrial safety systems. The NXR-S family combines remote safety I/O, built-in logic, and CIP Safety communication in a compact field-level architecture intended to support centralized management while placing I/O closer to safety devices.

A notable feature of the product line is that one NXR-S unit can communicate with multiple originators over CIP Safety, helping simplify safety-network integration where several controllers or network participants need access to safety-related status and control information.

What it does

NXR-S blocks provide safety remote I/O with built-in logic, allowing a unit to handle safety-related I/O functions without relying exclusively on a more centralized architecture. They use CIP Safety for safety communication and are designed for distributed control applications.

The blocks support single-cable connections that carry both power and safety signals for light curtains. This can reduce the number of separate field connections required for these devices. A built-in Web UI is provided for troubleshooting and unit replacement, giving maintenance personnel a direct interface for diagnostic and replacement tasks.

The family has an IP67 ingress-protection rating, supporting installation in industrial locations where protection against dust and water ingress is important. Listed electrical and environmental characteristics include 600 VAC dielectric strength and at least 20 MΩ insulation resistance between isolated circuits, operation from -10°C to +55°C, and installation up to 2,000 m altitude.

Applications

  • Distributed safety I/O architectures using CIP Safety communication
  • Safety-device connections near machinery or production equipment
  • Light-curtain installations using combined power and safety-signal cabling
  • Industrial cells requiring remotely located safety I/O with local built-in logic
  • Equipment where IP67-rated field-level safety modules are appropriate
  • Maintenance workflows that benefit from a built-in web interface for troubleshooting and unit replacement

Design considerations

  • Network integration: NXR-S uses CIP Safety and can communicate with multiple originators. System design should account for the required safety-network architecture and participating originators.
  • Field installation: The IP67 rating makes the blocks suited to protected field deployment, but enclosure, cable, connector, and installation choices should preserve the required system-level environmental protection.
  • Electrical isolation: The specified 600 VAC dielectric strength and 20 MΩ minimum insulation resistance apply between isolated circuits and should be considered when planning wiring and circuit separation.
  • Environmental limits: The stated operating range is -10°C to +55°C, with 25% to 85% storage humidity and no condensation. The maximum specified altitude is 2,000 m.
  • Safety-system engineering: The supplied information lists IEC 61508 and ISO 13849-1:2023 (4th edition) as applicable safety standards. Final safety-function design and validation remain system-level considerations.

Availability and further information

The source and datasheet links on this page provide further information on the Omron NXR-S Simple Logic Safety I/O Blocks, including detailed technical documentation and product-specific configuration information.

Data

Specifications

ManufacturerOmron Industrial Automation
Part numberTCC-2026-09-28-nxr-s-simple-logic-safety-i-o-blocks
SeriesNXR-S
TechnologyCIP Safety
Release date2026-09-28
Maximum altitude2000 m
Safety standardsIEC 61508 and ISO 13849-1:2023 (4th edition)
Shock resistance150 m/s² (3 times each in 6 directions along X, Y, and Z axes)
Dielectric strength600 VAC (between isolated circuits)
Safety communicationCIP Safety
Insulation resistance20 MΩ minimum (between isolated circuits)
Storage humidity range25% to 85% (with no condensation)
Ingress protection ratingIP67
Ambient operating temperature range-10°C to +55°C
Noise immunity on power supply line2 kV (conforms to IEC 61000-4-4)