Hydrogen Leak Detector (HLD) Analog Sensor - Honeywell
Sensors

Hydrogen Leak Detector (HLD) Analog Sensor

HoneywellTCC-2026-10-06-hydrogen-leak-detector-hld-analog-sensor

Honeywell HLD is an analog-voltage-output hydrogen leak sensor using thermal-conductivity detection to detect hydrogen concentrations from 1 ppm upward.

EHBSA Series Capacitors

Introduction

Honeywell’s HLD Analog Sensor is a hydrogen leak detector based on thermal conductivity detection (TCD). It provides an analog-voltage output for monitoring hydrogen concentrations from 1 ppm resolution across a 0% to 10% H₂ sensing range, equivalent to 0 to 100,000 ppm H₂.

The sensor combines a broad 8 V DC to 36 V DC supply range with operation from -40°C to +85°C, making it relevant where hydrogen-leak monitoring must be integrated into electrically powered equipment or fixed gas-handling installations. Honeywell specifies manual-intervention-free performance for 10 years and resistance to chemical poisoning.

What it does

The HLD detects hydrogen through changes in thermal conductivity and produces an analog voltage output for use by a host monitoring or control system. Its specified response time is under 2 seconds, while startup time is under 1 second.

Its sensing range covers low-level hydrogen detection through concentrations up to 10% H₂. Specified resolution is 1 H₂ppm. Accuracy is specified as ±10% full-scale from -40°C to +65°C across both the 0% to 4% and 4% to 10% H₂ ranges; over the full -40°C to +85°C operating range, specified accuracy is ±22% full-scale.

The sensor is specified for 10% to 90% relative humidity and atmospheric pressures from 80 kPa to 110 kPa. Typical current consumption is 10 mA at a 12 V DC supply or 5 mA at 24 V DC, with a 100 mA in-rush current specified at a 16 V supply.

Applications

Potential uses that follow from the sensor’s hydrogen-leak detection function include:

  • Monitoring around hydrogen storage tanks.
  • Hydrogen gas-piping leak detection.
  • Fuel-cell systems requiring analog hydrogen sensing.
  • Hydrogen monitoring within vehicle cabins.
  • Fixed installations that need an analog signal representing hydrogen concentration.

Design considerations

The HLD has an analog voltage output, so the receiving system needs an appropriate analog-input interface and interpretation of the sensor signal. System power design should accommodate the 8 V DC to 36 V DC supply range as well as the specified 100 mA in-rush current.

Environmental conditions should also be checked against the stated -40°C to +85°C operating temperature range, 10% to 90% RH humidity range, and 80 kPa to 110 kPa pressure range. For measurement performance, designers should account for the different full-scale accuracy specifications across the narrower -40°C to +65°C range and the full operating-temperature range.

Availability and further information

The source/distributor link and datasheet link on this page provide further information on the Honeywell HLD Analog Sensor, including detailed electrical, environmental, and integration data.

Data

Specifications

ManufacturerHoneywell
Part numberTCC-2026-10-06-hydrogen-leak-detector-hld-analog-sensor
SeriesHLD
FamilyHydrogen Leak Detector
TechnologyThermal Conductivity Detection (TCD)
Release date2026-10-06
Output typeAnalog voltage output
Startup time<1 s
Response time<2 s
In-rush current100 mA (16 V supply)
Sensed media range0 ppm to 100,000 ppm H₂
Hydrogen resolution1 H₂ppm
Supply voltage range8 V DC to 36 V DC
Hydrogen sensing range0% to 10% H₂
Relative humidity range10% to 90% RH
Atmospheric pressure range80 kPA to 110 kPA
Typical current at 12 V DC10 mA
Typical current at 24 V DC5 mA
Operating temperature range-40°C to +85°C
Accuracy at -40°C to +65°C±10% full-scale (0% to 4% and 4% to 10% H₂)
Accuracy at -40°C to +85°C±22% full-scale
Manual-intervention-free performance10 years