A2L Refrigerant Sensor - TE Connectivity
Sensors

A2L Refrigerant Sensor

TE ConnectivityTCC-2026-10-30-a2l-refrigerant-sensor

Refrigerant sensor family for detecting R-454B and R-32 gases at 10% LFL with automated self-calibration and no required field calibration.

EHBSA Series Capacitors

Introduction

TE Connectivity’s A2L Refrigerant Sensor is a gas-sensing module designed to detect R-454B and R-32 refrigerants. It uses thermal conductivity sensing and targets detection at 10% of the refrigerant’s lower flammability limit (LFL), making the family relevant to refrigerant leak-detection systems where early identification is required.

The design combines refrigerant sensing with integrated temperature and humidity measurement. These additional sensors provide environmental compensation across a wide operating range, while automated self-calibration is intended to maintain performance without field recalibration.

What it does

The sensor detects R-454B and R-32 gases with a specified accuracy of ±2.5% and a response time of 15 seconds. Its operating range extends from -40°C to +95°C and supports environments with up to 100% relative humidity.

Integrated temperature and humidity sensors compensate for changing environmental conditions. This is particularly important for installations that may encounter wide temperature swings or high moisture levels. The sensor is also designed to resist typical interference gases, helping to reduce the risk of sensor poisoning.

Automated self-calibration removes the requirement for routine field calibration. TE Connectivity specifies recalibration-free performance for up to 15 years, which can simplify long-term maintenance planning for installed sensing systems.

Applications

Potential applications based on the sensor’s stated function and specifications include:

  • R-454B and R-32 refrigerant leak-detection systems
  • HVAC equipment using A2L refrigerants
  • Fixed monitoring within refrigerant-handling equipment
  • Safety monitoring systems requiring detection at 10% LFL
  • Installations exposed to high humidity or broad operating temperatures

Design considerations

System designers should account for the sensor’s 15-second response time and specified 10% LFL detection level when defining alarm or control behavior. The operating environment must remain within the stated -40°C to +95°C temperature range and up to 100% relative humidity.

The integrated environmental compensation and automated self-calibration reduce external calibration requirements, but the supplied data does not specify package, mounting or electrical interface details. These aspects should therefore be confirmed from the available product documentation before mechanical or electrical integration.

The sensor lists compliance with UL and CSA 60335-2-40 Annex LL requirements, which may be relevant when incorporating it into equipment designed around those requirements.

Availability and further information

The Mouser Electronics source link on this page provides further product information. Consult the datasheet link when available for detailed electrical, mechanical and integration requirements.

Data

Specifications

ManufacturerTE Connectivity
Part numberTCC-2026-10-30-a2l-refrigerant-sensor
FamilyA2L Refrigerant Sensor
TechnologyThermal conductivity sensing
Release date2026-10-30
Accuracy±2.5%
CalibrationAutomated self-calibration (ASC)
Response time15s
Detected gasesR-454B and R-32
Detection level10% lower flammability limit (LFL)
Relative humidityUp to 100%
Requirements complianceUL and CSA 60335-2-40 Annex LL
Environmental compensationIntegrated temperature and humidity sensors
Operating temperature range-40°C to +95°C
Recalibration-free performanceUp to 15 years