ACHL-7348xU Current Sensors - Broadcom
Sensors

ACHL-7348xU Current Sensors

BroadcomTCC-2026-11-16-achl-7348xu-current-sensors

Fully integrated isolated Hall-effect linear current sensors for AC and DC measurement up to ±80A peak, with 600kHz typical bandwidth.

Avnet Silica Farming

Introduction

Broadcom’s ACHL-7348xU family comprises fully integrated, isolated Hall-effect linear current sensors for measuring AC and DC currents up to ±80 A peak. The devices combine a low-offset Hall IC with a copper conduction path, producing a voltage proportional to the measured current.

The family is notable for its 600 kHz typical bandwidth, fast overcurrent fault feedback and galvanic isolation in an SSO-12 package. These characteristics support current measurement and protection functions in power conversion and motor-control systems.

What it does

Current flows through the sensor’s internal copper conductor, while the Hall IC measures the resulting magnetic field. The device converts this measurement into a ratiometric voltage output referenced to its 5 V supply, allowing both positive and negative current to be represented.

The internal conductor has a typical resistance of 0.7 mΩ. Total output error is specified at ±1% typical, while the operating temperature range extends from -40°C to +125°C. In addition to its linear current output, the family provides overcurrent fault feedback with a typical response time of 0.8 μs.

For electrically demanding environments, the ACHL-7348xU sensors specify common-mode transient immunity above 25 kV/μs and an isolation voltage of 4.24 kVrms for one minute. Safety approvals listed for the family include IEC/EN 62368-1 and UL/cUL 1577.

Applications

Potential applications supported by the stated functions and specifications include:

  • AC or DC current measurement in motor drives
  • Motor phase-current and rail-current sensing
  • Current monitoring in industrial robots
  • Photovoltaic inverter current measurement
  • Isolated current feedback in power-conversion systems
  • Fast overcurrent detection and fault feedback

Design considerations

The ACHL-7348xU family requires a single 5 V supply and provides an output that is ratiometric to that supply. Interface circuitry should therefore account for supply variation when interpreting the output voltage.

The ±80 A peak sensing range, SSO-12 package and internal current-carrying conductor must be considered when planning PCB layout and current routing. Designs can also make use of the separate fast overcurrent feedback function where rapid fault indication is required.

Isolation voltage and common-mode transient immunity are explicitly specified, but system-level spacing, insulation and safety requirements still depend on the final application and board design.

Availability and further information

The Mouser Electronics source link on this page provides additional product information. The linked Broadcom datasheet contains the detailed electrical characteristics, package information and application guidance for the ACHL-7348xU family.

Data

Specifications

ManufacturerBroadcom
Part numberTCC-2026-11-16-achl-7348xu-current-sensors
SeriesACHL-7348xU
TechnologyHall effect
PackageSSO-12
Release date2026-11-16
Bandwidth600kHz typical
Output typeRatiometric from supply voltage
Supply voltage5V single supply
Safety approvalsIEC/EN62368-1, UL/cUL1577
Isolation voltage4.24kVrms, 1 minute
Total output error±1% typical
Current sensing range±80A PEAK
Output characteristicVoltage proportional to AC or DC current
Overcurrent fault feedback0.8μs typical
Operating temperature range-40°C to +125°C
Internal conductor resistance0.7mΩ typical
Common-mode transient immunity>25kV/μs